● Anti-overload design
● Large diameter dirty gas measurement
● It can be installed separately or remotely install MD09H loop display to realize remote operation
● 4~20mA, pulse or RS485 signal output
● With large-caliber online plug-in structure
Certification
Related Products
Loop Display Instrument |
Caliber range: DN25~DN2000
Measuring range: 0.3 m/s~12m/s (the initial flow velocity of water is 0.08m/s)
Accuracy: ±0.5%FS, ±1.0%FS
Body material: carbon steel+PTFE, 304+PTFE, titanium alloy
Target material: 316, titanium alloy, Hastelloy
Working temperature: -196℃~450℃
Power supply: 12V~32VDC, 3.6V battery pack
Output signal: two-wire system 4~20mADC (optional HART), four-wire system RS485-MODBUS-RTU, pulse
Explosion-proof mark: intrinsically safe Exia IIC T1~T6 Ga, explosion-proof Exd IIC T1~T6 Gb, dust explosion-proof Ex tD A21 IP66 T400℃~ T80℃
Surge (impact) immunity: 1KV line to line, 2KV line to ground
Protection level: IP66