● Design structure proven in practice
● Precision processing to ensure the consistency of parts
● Each unit has been carefully debugged to ensure stable set flow
● 100% water pressure test and air tightness test
● Single-channel, double-channel, panel installation and box installation, etc.
Measuring range: water 3~4000L/h, air 0.05~80Nm3/h (0.1013MPa, 0℃)
Measuring caliber: 1/4”~1”
Turndown ratio: 10:1
Accuracy grade: standard ±2.5%FS and ±4%FS, special ±1.5%FS and ±2.5%FS
Medium temperature: -80~+150℃
Maximum pressure: 10MPa
Wetted material: 304, 316, 316L and PTFE gasket
Process connection: thread 1/4"~1", ferrule Φ6~Φ20mm, flange DN15 and DN25